Normally the monitor detects a crashed service and restarts it. This can happen 3 times, then the monitor will give up.

To bring the service back online, without a whole VISULOX Service restart, the missing service can be restarted with the following method:

Restart via VISULOX command:

  • Log into the VISULOX Node where the service is missing.
  • Restart the service with:

    CODE
    visulox restart -service <vlxservice1>,<vlxservice2> ...

The parameters are the same as in service.conf.


Show available running VISULOX services:

CODE
visulox restart -service --?

running services:

    configuration  | importer       | router
    database       | monitor        | scripts
    dict           | objects2Portal | sessioncache
    download       | pin            | stats
    filecache      | policy         | store
    filecopy       | portal2node    | transitzone
    fileexchange   | publish        |
    health         | replication    |